Analytical evaluation and quality assessment of the ARKRAY ADAMS A1c Lite HA-8380V for HbA1c
https://pubmed.ncbi.nlm.nih.gov/37352386/ Received: February 10, 2023; accepted June 11, 2023; published online June 23, 2023 Abstract Introduction: ARKRAY ADAMS A1c Lite HA-8380V is a fully automated high- performance liquid chromatography system for the measurement of HbA1c. We aimed to evaluate its analytical performance using the Variant Mode. Methods: Carry-over, linearity, imprecision, trueness, interferences and comparison against…
-

Analytical evaluation and quality assessment ofthe ARKRAY ADAMS A1c HA-8190V for HbA1c
https://doi.org/10.1080/00365513.2023.2167231 Received: June 23, 2022; accepted Janualy 8, 2023; published online Janualy 18, 2023 Abstract ARKRAY ADAMS A1c HA-8190V is a fully automated high-pressure liquid chromatography (HPLC) system for the measurement of HbA1c. The runtime is 58 s per sample in the Variant mode and 24 s per sample in the Fast mode. We evaluated…
-

Performance evaluation of ARKRAY HA-8190V system for measuring glycated hemoglobin
https://biochimicaclinica.it/en/performance-evaluation-of-arkray-ha-8190v-system-for-measuring-glycated-hemoglobin-2/ Received: September 21, 2021; accepted October 7, 2021; published online October 26, 2021 Abstract Introduction: the new fully automated HPLC ion-exchange system ADAMS A1c HA-8190V analyzer, developed by ARKRAY Inc., running in two different modes (Variant and Fast) has been evaluated.Methods: reproducibility was evaluated according to the EP-15A3 standard. Method comparison was performed on…
-

Evaluation of the ARKRAY HA-8190V instrument for HbA1c
https://doi.org/10.1515/cclm-2020-1300 Received: August 25, 2020; accepted December 11, 2020; published online December 23, 2020 Abstract HemoglobinA1c (HbA1c) is the key parameter formonitoring of glycemic control in diabetic patients. Due to increased standardization, HbA1c is used more and more as diagnostic criterion as well. In 2011, the World Health Organization concluded that HbA1c could be used…
-

Sample transport and/or storage can cause falsely low HbA1c levels in blood cells measured by enzymatic assay
https://doi.org/10.1007/s13340-019-00416-7 Received: June 27, 2019; accepted December 31, 2019; published online November 19, 2019 Abstract Although HbA1c measurement by enzymatic assay (EA-HbA1c) is widely used in health-screening settings in Japan, recent studies have suggested lower EA-HbA1c levels as compared with HbA1c levels measured by high-performance liquid chromatography (HPLC-HbA1c). Hypothesizing that falsely low levels of EA-HbA1c…
-

Evaluation of four hemoglobin separation analyzers for hemoglobinopathy diagnosis
Received: November 9, 2016; accepted March 5, 2017; published online April 7, 2017
-

Analytical evaluation of the ADAMS™ A1c HA8180T analyzer for the measurement of HbA1c
Received: August 4, 2016; accepted December 28, 2016; published online February 25, 2017
-

Effects of Hemoglobin C, D, E and S traits on Measurements of Hemoglobin A1c by Twelve Methods
https://pubmed.ncbi.nlm.nih.gov/26828530/ Received: December 8, 2015; accepted January 28, 2016; published online January 29, 2016 Abstract Background—Hemoglobin C, D Punjab, E or S trait can interfere with hemoglobin A1c (HbA1c) results. We assessed whether they affect results obtained with 12 current assay methods. Methods—Hemoglobin AA (HbAA), HbAC, HbAD Punjab, HbAE and HbAS samples were analyzed on…