Évaluation analytique et évaluation de la qualité de l'ARKRAY ADAMS A1c Lite HA-8380V pour HbA1c
https://pubmed.ncbi.nlm.nih.gov/37352386/ Received: February 10, 2023; accepted June 11, 2023; published online June 23, 2023 Abstract Introduction: ARKRAY ADAMS A1c Lite HA-8380V is a fully automated high- performance liquid chromatography system for the measurement of HbA1c. We aimed to evaluate its analytical performance using the Variant Mode. Methods: Carry-over, linearity, imprecision, trueness, interferences and comparison against…
-

Évaluation analytique et évaluation de la qualité de l'ARKRAY ADAMS A1c HA-8190V pour HbA1c
https://doi.org/10.1080/00365513.2023.2167231 Received: June 23, 2022; accepted Janualy 8, 2023; published online Janualy 18, 2023 Abstract ARKRAY ADAMS A1c HA-8190V is a fully automated high-pressure liquid chromatography (HPLC) system for the measurement of HbA1c. The runtime is 58 s per sample in the Variant mode and 24 s per sample in the Fast mode. We evaluated…
-

Évaluation des performances du système ARKRAY HA-8190V pour la mesure de l'hémoglobine glyquée
https://biochimicaclinica.it/en/performance-evaluation-of-arkray-ha-8190v-system-for-measuring-glycated-hemoglobin-2/ Received: September 21, 2021; accepted October 7, 2021; published online October 26, 2021 Abstract Introduction: the new fully automated HPLC ion-exchange system ADAMS A1c HA-8190V analyzer, developed by ARKRAY Inc., running in two different modes (Variant and Fast) has been evaluated.Methods: reproducibility was evaluated according to the EP-15A3 standard. Method comparison was performed on…
-

Évaluation de l'instrument ARKRAY HA-8190V pour l'HbA1c
https://doi.org/10.1515/cclm-2020-1300 Received: August 25, 2020; accepted December 11, 2020; published online December 23, 2020 Abstract HemoglobinA1c (HbA1c) is the key parameter formonitoring of glycemic control in diabetic patients. Due to increased standardization, HbA1c is used more and more as diagnostic criterion as well. In 2011, the World Health Organization concluded that HbA1c could be used…
-

Le transport et/ou le stockage des échantillons peuvent entraîner des taux d'HbA1c faussement bas dans les cellules sanguines mesurées par dosage enzymatique
https://doi.org/10.1007/s13340-019-00416-7 Received: June 27, 2019; accepted December 31, 2019; published online November 19, 2019 Abstract Although HbA1c measurement by enzymatic assay (EA-HbA1c) is widely used in health-screening settings in Japan, recent studies have suggested lower EA-HbA1c levels as compared with HbA1c levels measured by high-performance liquid chromatography (HPLC-HbA1c). Hypothesizing that falsely low levels of EA-HbA1c…
-

Évaluation de quatre analyseurs de séparation d'hémoglobine pour le diagnostic de l'hémoglobinopathie
Reçu le 9 novembre 2016 ; accepté le 5 mars 2017 ; publié en ligne le 7 avril 2017
-

Évaluation analytique de l'analyseur ADAMS™ A1c HA8180T pour la mesure de l'HbA1c
Reçu le 4 août 2016 ; accepté le 28 décembre 2016 ; publié en ligne le 25 février 2017
-

Effets des caractéristiques de l'hémoglobine C, D, E et S sur les mesures de l'hémoglobine A1c par douze méthodes
https://pubmed.ncbi.nlm.nih.gov/26828530/ Received: December 8, 2015; accepted January 28, 2016; published online January 29, 2016 Abstract Background—Hemoglobin C, D Punjab, E or S trait can interfere with hemoglobin A1c (HbA1c) results. We assessed whether they affect results obtained with 12 current assay methods. Methods—Hemoglobin AA (HbAA), HbAC, HbAD Punjab, HbAE and HbAS samples were analyzed on…